APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2363 Issued:1963-06-18
Revised:2012-07-31
Style 2363 Parallel cable with extruded integral insulation and jacket

Rating60 deg C, no voltage assigned, FT2 flame, 60 deg C wet, Sunlight resistant.
Conductor12 AWG - 8 AWG, consisting of 30 AWG strands
InsulationExtruded PVC, integral with jacket See Facing Page for compound designation, or shall use any of the Recognized Component (QMTT2) 720 h Sunlight-Resistant PVC insulation and jacket compounds.
Conductor sizeMinimum average thicknessMinimum thickness at any pointMinimum web thickness
12 AWG60 mils54 mils72 mils
10-8 AWG80 mils72 mils72 mils
AssemblyTwo conductors, same as Type SPT-3 flexible cord except rippable web is optional. If provided, groove depth is approx 45 mils and width is approx 30 mils, or may include a "V" groove where the minimum thickness at bottom of groove is 5 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseLow voltage outdoor application in lighting fixtures. Polarity identification may be omitted.