Rating | 60 deg C, no voltage assigned, FT2 flame, 60 deg C wet, Sunlight resistant. |
|
Conductor | 12 AWG - 8 AWG, consisting of 30 AWG strands |
|
Insulation | Extruded PVC, integral with jacket See Facing Page for compound designation, or shall use any of the Recognized Component (QMTT2) 720 h Sunlight-Resistant PVC insulation and jacket compounds. |
| Conductor size | Minimum average thickness | Minimum thickness at any point | Minimum web thickness |
| 12 AWG | 60 mils | 54 mils | 72 mils |
| 10-8 AWG | 80 mils | 72 mils | 72 mils |
|
Assembly | Two conductors, same as Type SPT-3 flexible cord except rippable web is optional. If provided, groove depth is approx 45 mils and width is approx 30 mils, or may include a "V" groove where the minimum thickness at bottom of groove is 5 mils. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Low voltage outdoor application in lighting fixtures. Polarity identification may be omitted. |
|