APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2369 Issued:1963-09-10
Revised:2011-09-30
Style 2369 Parallel Cable with Extruded Integral Insulation.

Rating80 deg C, 600 Vac, FT2 flame, 60 deg C Wet. Optional - 60 or 80 deg C Oil.
Conductor14, 12 or 10 AWG stranded, consisting of 30 AWG or smaller strands.
InsulationExtruded PVC, nomimal 80 mils wall thickness, the following minimum thickness (pin gauge) dimensions: Wall thickness: 70 mils, Web thickness: 141 mils, Wall after rip: 58 mils.
AssemblyTwo conductors, same as type SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where exposed to temperatures not exceeding 80 deg C; or ditto where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C (whichever is applicable); Moisture Resistant, 60 deg C. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024