APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2370 Issued:1963-09-10
Revised:2011-12-21
Style 2370 Parallel cable with extruded integral insulation and jacket

Rating80 deg C, 600 Vac, FT2 flame, Oil Res 60 or 80 deg C (optional), Moisture Res 60 deg C
ConductorThree No. 14, 12 or 10 AWG consisting of 30 AWG or smaller tinned or bare copper.
InsulationIntegral with Jacket. PVC, nomimal 80 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.141 in., Wall after rip: 0.058 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where exposed to temperature not exceeding 80 deg C; or where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C; (whichever is applicable); Moisture Resistant, 60 deg C. Polarity identification may be omitted.