APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2373 Issued:1963-12-09
Revised:2011-10-28
Style 2373 Multiple-conductor cable with non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded.
InsulationExtruded PE or extruded FRPE, 16 mils min average, 13 mils minimum at any point.
AssemblyTwo conductors.
CoveringOptional, lacquered glass or rayon over one or both conductors.
ShieldShielding over one or both conductors may consist of 38-30 AWG tinned copper strands applied as a wrap or braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Mylar with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 16 mils min average, 13 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.
UseFor Electronic Use In Non-Hazardous Locations or Phonograph Pick-up Cable. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.