APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2374 Issued:1963-12-09
Revised:2011-10-11
Style 2374 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor24 AWG - 22 AWG solid or stranded.
Insulated ConductorTwo No. 22 AWG Style No. 1007; One No. 22 AWG, Style No. 1187; One No. 22 or 24 AWG, Style No. 1108; or one No. 22 or 24 AWG, Style No. 1107.
AssemblyConductors shall be cabled into a concentric cable with a cotton or jute center filler and a cotton binder applied over the cabled conductors.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment where temperature does not exceed 60 deg C.