APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2385 Issued:1964-03-24
Revised:2013-01-10
Style 2385 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, Cable flame.
Insulated Conductor40 AWG minimum. Labeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional, extruded PVC, 6 mils minimum thickness at any point, over conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket*Minimum average thicknessMinimum thickness at any point
0.700 inch or less60 mils48 mils
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring in Class 2 circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024