APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2392 Issued:1964-06-01
Revised:2012-07-13
Style 2392 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 14 AWG solid or stranded round.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point. Same as Type SJT: except insulation colors are not specified.
AssemblyThree conductors.
ShieldOptional. Shielding over one or more of the insulated conductors shall consist of 38-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024