APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2395 Issued:1964-06-29
Revised:2011-08-11
Style 2395 Multiple-Conductor Cable with Extruded Insulation and Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor22 AWG - 16 AWG, stranded
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Conductors A, B, and C shall have a nominal 15 mil wall; Conductors D and E shall have a nominal 30 mil wall, otherwise same as Type SJT Cord.
AssemblyFive conductors. A, B, and C - No. 22 AWG; D and E - No. 16 AWG. All may be provided with a lacquered rayon braid. Conductors A, B, and C shall be provided with a copper braid shield (six 40 AWG strands in each of sixteen carriers, eighteen picks per inch). Shielded conductors A, B, and C shall be cabled with a 3-1/2 inch left-hand lay; unshielded conductors D and E shall be twisted together in a 3-1/2 inch right-hand lay. The two groups shall be twisted together with a 3-1/2 inch lay.
JacketExtruded PVC, 60 mils minimum average thickness, 48 mils minimum thickness at any point, except type SJT cord.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use with Electric Organs.