APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2400 Issued:1964-07-24
Revised:2011-12-21
Style 2400 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, FT2 flame.
ConductorFour No. 20, 22, or 24 AWG.
InsulationPVC, 15 mils min average, 13 mils minimum at any point.
Assemblysame as type SVT.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting Phonograph Amplifiers or Sound Equipment where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024