APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2404 Issued:1964-10-23
Revised:2012-04-19
Style 2404 Parallel cable with extruded integral insulation and jacket.

Rating80, 90, 105 deg C, Voltage not specified, Horizontal flame.
Conductor22 AWG - 20 AWG solid or stranded round, tinned or bare copper.
InsulationIntegral with Jacket. Extruded PVC, The following mininum dimensions shall apply: Wall thickness: 20 mils, Web thickness: 55 mils, Wall after rip: 15 mils.
AssemblyTwo conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor the low voltage audio circuits within the enclosure of radio, television, and phonograph equipment