APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2405 Issued:1965-01-27
Revised:2013-01-07
Style 2405 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to Six conductors. Singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
ShieldOptional.
JacketOptional. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.