APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2415 Issued:1965-08-31
Revised:2012-07-25
Style 2415 Multi-conductor Cable with Extruded Insulation and Extruded Non-integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorNo. 22 AWG - 16 AWG stranded. Two No. 16 AWG stranded 26/30 AWG tinned copper, Style 1012; and four No. 22 AWG, stranded 7/30 AWG tinned copper, Style 1008. Both styles use a rayon braid, lacquered finish.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblySix conductors,twisted together and the interstices filled with jute, and a cotton braid over the assembly.
BraidOptional.
JacketExtruded PVC, 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or Internal Wiring In Electric Organs.

UL and the UL Logo are trademarks of UL LLC © 2024