APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2416 Issued:1965-09-15
Revised:2011-09-27
Style 2416 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 90 deg C, 300 Vac, 600 Vdc, Horizontal Flame.
Conductor24 AWG - 16 AWG, stranded. Insulated conductor number 1: 24 AWG, Style 1118 with braided shield of 38 AWG strands and jacket. Insulated conductor numbers 2 to 8: 16 AWG (26 x 30) Style 1013. Insulated conductor numbers 9 to 15: 20 AWG (10 x 30) Style 1013.
Insulated ConductorLabeled Style 1013 and 1118.
AssemblyFifteen insulated conductors cabled into a round cable with 4 in. maximum length of lay. Binder threads provided; fillers or wraps are optional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use with electric organs.

UL and the UL Logo are trademarks of UL LLC © 2024