Rating | 90 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C, Moisture Resistant 60 deg C |
|
Conductor | 50 AWG - 10 AWG solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | PVC, 45 mils min average. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of appliances or electronic equipment at temperatures not exceeding 90 deg C dry, 60 deg C wet, and 60 deg C in oil. |
|