APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2424 Issued:1966-03-04
Revised:2012-07-19
Style 2424 Multiple Conductor using Non-integral Jacket.

Rating90 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C, Moisture Resistant 60 deg C
InsulationLabeled or complying with this Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) A 6 mil or thicker PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC, 80 mils minimum average thickness, 64 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliance or electronic equipment.