APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2425 Issued:1966-03-04
Revised:2012-07-16
Style 2425 Multiple-conductor Cable using nonintegral jacket.

Rating90 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C , Moisture Resistant 60 deg C
InsulationLabeled AWM or singles complying with this manufacturer's AWM Procedure.
AssemblyTwo or more conductors. Two conductor cable may be flat or twisted. If more than one group is used, groups shall be twisted together. (The length of lay of the twisted conductors or groups is not specified). Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap, serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded PVC, 110 mils min average, 88 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal and internal wiring.