Rating | 90 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C, Moisture Resistant 60 deg C |
|
Conductor | 50 AWG - 10 AWG solid or stranded round. |
|
Insulation | Labeled AWM or singles complying with this Manufacturer's AWM Procedure. |
|
Assembly | Two or more conductors. Two conductor cable may be flat or twisted. If more than one group is used, groups shall be twisted together. (The length of lay of the twisted conductors or groups is not specified). Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap, serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | PVC, 140 mils min average. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of appliance or electronic equipment at temperatures not exceeding 90 deg C dry, 60 deg C wet, and 60 deg C in oil. |
|