APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2428 Issued:1966-04-19
Revised:2011-08-04
Style 2428 Multiple-Conductor Cable with Extruded Insulation and Extruded Non-Integral Jacket

Rating80 deg C, Voltage not specified, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round
InsulationExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point
AssemblyTwo to six conductors.
ShieldOptional.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.