APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2429 Issued:1966-04-12
Revised:2011-08-04
Style 2429 Parallel Cable with Extruded Integral Insulation and Jacket

Rating80 deg C, 300 Vac, FT2 flame, Optional - 60 or 80 deg C oil
Conductor18 AWG - 16 AWG solid or stranded, consisting of 30 AWG or smaller stranding.
InsulationPVC, 45 mils minimum average thickness, 40 mils minimum thickness at any point.
AssemblyTwo conductor, same as type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliance where exposed to temperatures not exceeding 80 deg C and not subjected to repeated flexing; additional optional rating 60 deg C or 80 deg C in oil, whichever is applicable. Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024