APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2430 Issued:1966-05-20
Revised:2012-03-09
Style 2430 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating90 deg C, 300 Vac, Horizontal flame.
ConductorInsulated Conductor A: 24 AWG, stranded, 7/32 AWG tinned; Insulated Conductor B: 22-16 AWG, stranded, tinned.
InsulationInsulated Conductor A: Refer to Style 1009; Insulated Conductor B: Refer to Style 1013.
AssemblyOne Insulated Conductor A, covered by lacquered rayon braid, tinned copper shield and 0.032 in. PVC jacket; thirteen Insulated Conductor B's. The conductors shall be twisted together with cotton or oriented polyethylene terephthalate separator. Fillers are optional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn Electric Organs.

UL and the UL Logo are trademarks of UL LLC © 2024