APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2431 Issued:1966-07-14
Revised:2012-04-25
Style 2431 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, horizontal flame.
Conductor22 AWG - 18 AWG stranded copper.
InsulationLabeled Style 1007 and Type TFF.
AssemblySix conductors. Style 1007 are paired and each pair twisted together. The pair of Style 1007 wires twisted together with the pair of Type TFF wires. The assembly twisted together with a lay of conductors of 3.5 in. A cotton filler is provided through the center of the assembly. Over the assembly is PVC material to fill the valleys between conductors. Individual conductor insulations may be colored for circuit identification.
FillerRequired. Cotton.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as connection of a power pack unit to a portable television receiver where exposed to temperatures not exceeding 60 deg C, and the maximum length should not exceed 18 inches.