Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | Tinsel conductors composed of six strands, each strand having two flattened cadmium copper wires (rolled from 40 AWG wire). The two flattened cadmium copper wires shall be wound around a Polyester yarn core and all six strands cabled around a center core of Polyester yarn. Conductor covered with a braid of nylon or cotton. |
|
Insulation | Extruded PVC, 15 mils minimum average thicknes, 13 mils minimum thickness at any point. |
|
Assembly | Four tinsel conductors, Same as for Type SVT, but with a lay of twist conductor opposite in direction to the direction in which the helical cord is wound. The cord is heat treated while coiled in a helical shape on a mandrel. When the helix is stretched out and released, the cord returns to its helical form because of the elasticity of the jacket. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Suitable for hand set cord of telephones for use in Hazardous Locations. |
|