APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2446 Issued:1967-06-08
Revised:2011-09-27
Style 2446 Multiple-conductor cable using non-integral jacket

Rating80 deg C insulation, 105 deg C jacket, 600 Vac, Horizontal flame.
Conductor18 AWG, stranded.
InsulationExtruded PVC, 30 mils min average thickness.
AssemblySeven to ten insulated conductors. All the insulated conductors may be twisted together in one group. The length of lay of the twisted insulated conductors or groups is not specified. Fillers may be used in the cable but are not required.
JacketExtruded PVC, 30 mils min average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of refrigerated coin-operated vending machines at temperatures not exceeding 105 deg C for jacket and 80 deg C for individual insulated conductors.

UL and the UL Logo are trademarks of UL LLC © 2024