Rating | 80 deg C insulation, 105 deg C jacket, 600 Vac, Horizontal flame. |
|
Conductor | 18 AWG, stranded. |
|
Insulation | Extruded PVC, 30 mils min average thickness. |
|
Assembly | Seven to ten insulated conductors. All the insulated conductors may be twisted together in one group. The length of lay of the twisted insulated conductors or groups is not specified. Fillers may be used in the cable but are not required. |
|
Jacket | Extruded PVC, 30 mils min average thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of refrigerated coin-operated vending machines at temperatures not exceeding 105 deg C for jacket and 80 deg C for individual insulated conductors. |
|