Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | 22 - 18 AWG, each consisting of 30 AWG tinned copper strands. |
|
Insulation | Extruded PVC, 30 mils min average, 27 mils minimum at any point. |
|
Assembly | Six conductors, The shielded group of conductors is twisted together with conductors E and F and fillers, and a wrap of cotton, paper tape, or Polyester tape is applied. |
|
Shield | Conductive cotton wrap applied helically over twisted assembly of drain wire, fillers, and conductors, A, B, C, and D. In lieu of the conductive cotton wrap, one of the following shielding tapes may be employed. Laminated tape, consisting of 0.00035 in. aluminum foil, 0.001 in. "Polyester" tape, 0.00035 in. aluminum foil. Laminated tape, consisting of 0.00035 in. aluminum foil, 0.0005 or 0.001 or 0.002 in. "Polyester" tape. Laminated tape, consisting of 0.00035 in. aluminum foil, No. 150 1/0 fiberglas yarn reinforcement, 0.0005 in. "Polyester" tape. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|