APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2457 Issued:1968-02-15
Revised:2012-04-19
Style 2457 Multiple Conductor with Extruded Insulation and Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 10 AWG solid or stranded round.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyFive conductors, same as type SJT.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. Complete cord wound on mandrel and heat treated to provide helical shape.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn couches and hospital beds.

UL and the UL Logo are trademarks of UL LLC © 2024