Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | 24 AWG - 10 AWG, stranded. |
|
Insulation | CONSTRUCTION A and C - Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
CONSTRUCTION B - Extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
Assembly | CONSTRUCTION A and C - two to seven insulated conductors, same as Type SVT.
CONSTRUCTION B - two to nine insulated conductors, same as Type SJT.
All construction - Different conductor sizes may be employed in one cord, no polarity identification required. |
|
Shield | Optional - One or more of the individually insulated conductors may be shielded or groups of individually insulated conductors may be shielded. Shielding over conductor shall consist of 36 AWG - 30 AWG tinned or untinned copper strands applied as a wrap or braid. |
|
Jacket | CONSTRUCTION A and B - Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
Construction C - Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | CONSTRUCTION A - Internal wiring.
CONSTRUCTION B - Internal or external wiring.
CONSTRUCTION C - External wiring for Lighting Fixtures. |
|