Rating | 80 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional, Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
|
Jacket | Extruded PVC. |
| Diameter of assembly under jacket | Construction A - Minimum average thickness | Construction A - Minimum thickness at any point | Construction B - Minimum average thickness | Construction B - Minimum thickness at any point |
| 0.425 inches or less | 30 mils | 24 mils | 45 mils | 36 mils |
| 0.425-0.700 inches | 60 mils | 48 mils | 60 mils | 48 mils |
| 0.701-1.500 inches | 80 mils | 64 mils | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal wiring of X-ray Equipment, or in the internal or exteral interconnection of electronic equipment. Construction B: External interconnection of electronic equipment in abuse areas, such as X-ray Equipment and Business Machines. |
|