APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2465 Issued:1968-05-02
Revised:2012-07-26
Style 2465 Multi-conductor cable with extruded insulation and non-integral jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor22 AWG - 18 AWG consisting of 30 AWG or smaller stranded.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyNine conductors. A, B, C, D, E, F, and G--22 AWG; H and I--18 AWG; each consisting of 30 AWG tinned copper strands; drain wire 18 AWG, consisting of 34 or 36 AWG strands. The shielded group of conductors is twisted together with conductors H and I and fillers, and a wrap of cotton, paper tape, or Mylar tape is applied.
ShieldConductive cotton wrap applied helically over twisted assembly of drain wire, fillers, and conductors, A, B, C, D, E, F, and G. Alternatively the drain wire strands may be wrapped around one of the No. 22 AWG insulated conductors assembled in the outer layer of the shielded assembly. In lieu of the conductive cotton wrap, one of the following shielding tapes may be employed: Laminated tape, consisting of 0.00035 in. aluminum foil, 0.001 in. "Polyester" tape, 0.00035 in. aluminum foil. Laminated tape, consisting of 0.00035 in. aluminum foil, 0.0005 or 0.001 or 0.002 in. "Polyester" tape. Laminated tape, consisting of 0.00035 in. aluminum foil, No. 150 1/0 fiberglas yarn reinforcement, 0.0005 in. "Polyester" tape.
JacketExtruded PVC, 45 mils min average, 36 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use with electronic pianos.

UL and the UL Logo are trademarks of UL LLC © 2024