Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | 22 AWG - 18 AWG consisting of 30 AWG or smaller stranded. |
|
Insulation | Extruded PVC, 30 mils min average, 27 mils minimum at any point. |
|
Assembly | Nine conductors. A, B, C, D, E, F, and G--22 AWG; H and I--18 AWG; each consisting of 30 AWG tinned copper strands; drain wire 18 AWG, consisting of 34 or 36 AWG strands. The shielded group of conductors is twisted together with conductors H and I and fillers, and a wrap of cotton, paper tape, or Mylar tape is applied. |
|
Shield | Conductive cotton wrap applied helically over twisted assembly of drain wire, fillers, and conductors, A, B, C, D, E, F, and G. Alternatively the drain wire strands may be wrapped around one of the No. 22 AWG insulated conductors assembled in the outer layer of the shielded assembly. In lieu of the conductive cotton wrap, one of the following shielding tapes may be employed: Laminated tape, consisting of 0.00035 in. aluminum foil, 0.001 in. "Polyester" tape, 0.00035 in. aluminum foil. Laminated tape, consisting of 0.00035 in. aluminum foil, 0.0005 or 0.001 or 0.002 in. "Polyester" tape. Laminated tape, consisting of 0.00035 in. aluminum foil, No. 150 1/0 fiberglas yarn reinforcement, 0.0005 in. "Polyester" tape. |
|
Jacket | Extruded PVC, 45 mils min average, 36 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use with electronic pianos. |
|