APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2466 Issued:1968-05-14
Revised:2008-05-27
Style 2466 Flat Cable.

Rating80 deg C, no voltage assigned, Horizontal flame.
Conductor30 AWG - 24 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, Insulation minimum thickness; backing layer 0.006 in.; intermediate layer 0.010 in.; top layer 0.006 in. Top layer forms ridges over conductors. Total thickness 0.040 in. minimum.
AssemblyEight to seventy-five conductors laid parallel, spaced 0.025 in. minimum on centers. One end conductor or both may be in electrical contact with ground plane. Ground Plane. Expanded copper, thickness 0.003 in. minimum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, such as electronic computers and electric business machines.
 