APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2468 Issued:1968-05-07
Revised:2018-11-08
Style 2468 Flat ribbon cable

Rating80 deg C, 300 Vac, Horizontal flame. Optional - 60 or 80 deg C Oil.
Conductor2-150, Nos. 32-16 AWG. Tinned or bare, solid or stranded copper, conductors laid parallel and in one plane. Same or mixed AWG.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to one hundred and fifty conductors laid parallel and in one plane. May use same or mixed AWG size. Minimum average and minimum at any point of insulation thickness after ripping shall be 15 mils and 13 mils, respectively. This forms a flat cable with a single row of conductors having a 1/2 in. maximum width web between insulated conductors.
ShieldOptional.
CoveringOptional, extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024