APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2476 Issued:1968-10-08
Revised:2012-03-21
Style 2476 Bonded or Laminated Flat Ribbon Cable.

Rating80 deg C, 300 Vac, Horizontal Flame.
InsulationLabeled AWM or Complying with Manufacturer's Procedure.
AssemblyTwo to one hundred conductors bonded together in such a fashion to form a flat ribbon-type cable or to solid or cellular PVC or irradiated PVC sheet, or 0.2 mil minimum polyester or PVC adhesive, or 0.2 mil minimum Mylar film bonded with 3 mil minimum PVC. The cable may be of the same AWG size of mixed AWG sizes. Similar cables may be formed from twisted pairs bonded together.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024