Rating | 60 deg C, voltage rating not specified, Cable flame. |
|
Conductor | 36 AWG minimum, solid or stranded round |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure |
|
Assembly | Two or more singles, twisted pairs or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional |
|
Covering | Optional - A thermoplastic covering may be extruded over one or more groups of conductors (each group consisting of two or more conductors). |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 inch or less | 60 | 48 |
| 0.701-1.500 inch | 78 | 64 |
| 1.501-2.500 inch | 110 | 88 |
| 2.500 inch and larger | 140 | 112 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of computers and electronic equipment |
|