Rating | 60 deg C, Voltage rating not specified, Cable flame. |
|
Insulated Conductor | 30-16 AWG, solid or stranded. Labeled or complying with Manufacturer's AWM Procedure except that AWM rated 30 volts for use in Class 2 circuits cannot be used. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 45 mils | 36 mils |
| 0.426-0.700 inch | 60 mils | 48 mils |
| 0.701-1.000 inch | 80 mils | 64 mils |
| * - Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnect of electronic equipment. |
|