APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2494 Issued:1969-10-13
Revised:2011-12-21
Style 2494 Multiple-conductor cable using non-integral jacket

Rating60 deg C, no voltage assigned, Horizontal flame.
Conductor28 AWG - 15 AWG solid or stranded round, tinned or bare copper. Different conductor sizes may be employed in one cord.
InsulationClass 43, 20-mil nominal wall of thermoplastic (PVC). Only those colors listed on the Facing Page may be employed.
Shield(Optional) - Over one or more insulated conductors. Shielding over conductor insulation shall consist of No. 38-30 AWG, tinned or untinned copper strands applied as a wrap or braid, a wrap of aluminum faced polyethylene terephthalate tape with a parallel uninsulated drain wire, or a wrap of copper foil.
JacketClass 43, 15 mil nominal wall of thermoplastic (PVC). Only those colors listed on the Facing Page may be employed.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of x-ray equipment where not exposed to abuse.

UL and the UL Logo are trademarks of UL LLC © 2024