APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2495 Issued:1969-12-03
Revised:2012-04-12
Style 2495 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 600 Vdc, Horizontal flame.
Conductor22 AWG - 18 AWG consisting of 30 AWG or smaller stranded, tinned or bare copper.
InsulationExtruded PVC, Conductors A, E, F, G, H, I, J 15 mils min average, 13 mils minimum at any point. Conductors B, C, D - 30 mils min average, 27 mils minimum at any point.
AssemblyTen conductors cabled with nominal 4 in. right hand lay. Conductor A - 18 AWG. Conductors B, C, D, G, H, I, and J -22 AWG. Conductors E and F -20 AWG. Fillers, binders and wrap over core optional.
ShieldTinned or untinned copper braid or wrap on Conductor A. Tinned or untinned copper braid over assembly of all conductors.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point. 15 mil wall over Conductor A shield; 30 mil wall overall.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting cable for electronic equipment.