Rating | 105 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG min, solid or stranded. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 milsg | 88 mils |
| 2.501 inch and larger | 140 mils | 112 mils |
| * - Major diameter if cable is flat or oval. |
|
Covering | Optional, braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|