APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2505 Issued:1970-07-09
Revised:2008-05-27
Style 2505 Flat Cable.

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 4 AWG round or flat. If flat, Minimum width 20 mils, maximum width 2-1/2 inches. Minimum thickness 1 mil, maximum thickness 15 mils.
InsulationOn each side of the conductors 3 mils minimum at any point. Oriented Polyethylene Terephthalate bonded together with minimum 25 mil insulation width on outside edges of conductors and 25 mil minimum width insulation between adjacent conductors.
AssemblyTwo through 100 conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic computers and electric business machines.