APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2509 Issued:1970-08-12
Revised:2012-11-01
Style 2509 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo to 150 individually insulated conductors or groups of conductors cabled together into a round cable. Lay not specified. Fillers or wraps optional. Fillers or wraps optional.
ShieldNot permitted.
JacketExtruded PVC, 10 mils min average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.