APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2511 Issued:1970-09-11
Revised:2012-04-03
Style 2511 Multiple-conductor cable using non-integral jacket

Rating60 deg C, voltage rating not specified, Horizontal flame.
Conductor and AssemblySubassembly A - 4 of 18 AWG copper with 30 mils wall of extruded PVC, which complies with Section 1. Conductors are cabled with a 22 AWG drain wire, polyester aluminum shield and 0.003 inches polyester tape overall. Subassembly B - 75 ohm coax, 22 AWG (7x30) tinned copper center conductor, 0.058 inches natural extruded foamed PP insulation, braid shield, 0.020 inches wall extruded PVC jacket. (Style 1354). Subassembly C - 7 of 22 AWG copper with 15 mils wall of extruded PVC which complies with Section 1. Conductors are color coded and cabled together. Subassembly D - 7 of 22 AWG copper with 15 mils wall of extruded PVC which complies with Section 1. Conductors are color coded and cabled together with a 22 AWG drain wire and a polyester aluminum shield overall.
AssemblyOne each of subassembly A and D, two of subassembly C, three of subassembly B cabled together with fillers and an overall polyester tape (0.001 inches) wrap.
ShieldTinned copper braid over assembly.
JacketExtruded PVC, 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseTV Camera Cable.

UL and the UL Logo are trademarks of UL LLC © 2024