APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2515 Issued:1970-10-21
Revised:2012-07-03
Style 2515 Multiple Conductor with Extruded Insulation and Extruded Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor22 AWG consisting of twenty-six 36 AWG.
InsulationExtruded PVC, 30 mils minimum thickness average, 27 mils minimum thickness at any point.
AssemblySeven conductors, same as type SJT.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn couches and hospital beds.

UL and the UL Logo are trademarks of UL LLC © 2024