APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2517 Issued:1970-10-21
Revised:2018-04-24
Style 2517 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Cable Flame.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure. 40 AWG minimum.
AssemblyConsists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded PVC.
Diameter of Core Assembly under Jacket@Minimum Average ThicknessMinimum Thickness at any point
0.700 inch or less30 mils24 mils
0.701 - 1.000 inch45 mils36 mils
1.001 - 1.500 inch60 mils48 mils
1.501 - 2.500 inch80 mils64 mils
@ - Major diameter if cable is flat or oval.
BraidOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: "600 Volts peak for Electronic Use Only".