Rating | 105 deg C, 300 Vac, Cable Flame. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure. 40 AWG minimum. |
|
Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of Core Assembly under Jacket@ | Minimum Average Thickness | Minimum Thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701 - 1.000 inch | 45 mils | 36 mils |
| 1.001 - 1.500 inch | 60 mils | 48 mils |
| 1.501 - 2.500 inch | 80 mils | 64 mils |
| @ - Major diameter if cable is flat or oval. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: "600 Volts peak for Electronic Use Only". |
|