APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2521 Issued:1971-03-03
Revised:2012-03-09
Style 2521 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 150 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded SRPVC, 10 mils minimum average thickness, 9 mils minimum thickness at any point
Shield36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
CoveringOptional, over insulated singles extruded nylon 4 mils minimum avgerage thickness, 3 mils minimum thickness at any point.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment Where Not Exposed to Movement or Mechanical Abuse.

UL and the UL Logo are trademarks of UL LLC © 2024