APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2531 Issued:1971-05-27
Revised:2011-10-03
Style 2531 Bonded or laminated flat ribbon cable.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor35 AWG - 21 AWG bare, flat solid copper. Thickness variable from 1-1/2 to 6 mils; width variable from 20 mils to 110 mils.
InsulationOn one side of conductors 6.5 mil minimum at any point layer of non-extruded PVC; on other side of conductors 6.5 mil minimum at any point layer of non-extruded PVC bonded to a minimum thickness of 1 mil PET. Insulated width on outer edges of strip not less than 45 mils and not less than 18 mils between adjacent conductors.
AssemblyTwo to 100 conductors laid parallel and in one plane. Length of insulated conductors not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024