APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2536 Issued:1971-06-25
Revised:2012-04-03
Style 2536 Multiple-Conductor cable using Non-integral Jacket.

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor26 AWG or 22 AWG, solid or stranded.
InsulationExtruded PE, 15 mils minimum average, 13 mils minimum at any point.
AssemblyTwo conductors laid parallel.
CoveringIndividual braids, cotton, rayon or fibered glass.
ShieldNo. 38-30 AWG, tinned or untinned copper strands applied as braid or wrap; or wrap of aluminum faced Polyester tape with parallel uninsulated drain wire applied over conductor assembly.
JacketExtruded PVC, 15 mils minimum average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring. As phonograph pick-up cable and for electronic use in nonhazardous locations.