APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2544 Issued:1971-07-19
Revised:2012-06-30
Style 2544 Flat Cable using Non-Integral Extruded Jacket

Rating80 deg C, 600 Vac, Horizontal Flame.
Conductor20-18 AWG, Stranded Round.
InsulationLabeled Style 1015.
AssemblyThirty-two conductors - One 18 AWG stranded copper wire on each edge of cable. Thirty 20 AWG stranded copper wire located between the two outer conductors. Conductors are laid parallel to each other at a nominal distance of 0.165 in. center to center. The jacket is applied over the insulated conductor. The entire assembly is approximately 5.25 in. wide and approximately 0.125 in. thick from top to bottom.
JacketExtruded PVC, 8 mils minimum thickness. 16 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.