APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2545 Issued:1971-07-19
Revised:2012-07-13
Style 2545 Parallel Cable with Extruded Non-integral Jacket.

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor28-20 AWG stranded round.
InsulationLabeled style 1015.
AssemblyTwenty-nine conductors, in each layer, are laid parallel to each other at a nominal distance of 0.165 in. center to center. Two 18 AWG on one edge and four 18 AWG on the other edge of each layer. Twenty-three 20 AWG located between the two groups 18 AWG wires in each layer. A total of 58 conductors. The jacket is applied over the insulated conductor. The two layers are placed back to back with a nominal 0.030 in. thick layer of adhesive between the two layers. The entire assembly is approximately 5 in. wide with an over-all thickness of approximately 0.330 in.
JacketExtruded PVC, 16 mils maximum wall thickness, 8 mils minimum wall thickness over the insulated conductors, top side. The back side has a 30 mils maximum and a 20 mils minimum wall thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.