This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 2547 Issued:1971-10-15
Revised:2013-02-27
Style 2547 Multiple-conductor cable using non-integral jacket

Rating80 deg C, Voltage Not Specified, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded SRPVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
AssemblyTwo or three conductors laid parallel, twisted, or cabled together, length of lay is not specified. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
ShieldOptional.
JacketOptional. Extruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not exposed to movement or mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2026