APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2553 Issued:1971-12-15
Revised:2011-12-21
Style 2553 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
InsulationLabeled Singles: three sytle 1007, one style 1115, Assembly and three type TFF wires
AssemblySeven conductors twisted together with cotton fillers and wrapped with paper tape, lay not specified.
ShieldOptional.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external Interconnecting Cable for Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024