Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 29 AWG - 20 AWG, copper, copper-clad steel, copper alloy, bare, tinned or silver-coated, having a minimum of 40 per cent conductivity.
|
|
Insulation | Over the conductor shall be applied a spiral wrap of flame-retardant polyethylene thread nominally 15 mils in diameter, approximately 1/2 in. between turns. This assembly shall be enclosed with a flame-retardant polyethylene tube having an approximately 15 mil wall.
|
|
Shield | A shield over each tube shall consist of a wrap of aluminum faced "Mylar" tape with a drain wire applied under the shield.
|
|
Assembly | Cable consists of two to nine conductors, laid flat to form a ribbon type cable with a maximum width of one inch.
|
|
Jacket | Extruded PVC, 47 mils minimum average thicknes, 43 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|