Rating | 60 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 18 AWG - 10 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 47 mils minimum average thickness, 43 mils minimum thickness at any point. |
|
Assembly | Two Through Ten Conductors. Different conductor sizes may be used in one cord. Two conductors may be laid parallel or twisted together. Three or more conductors shall be twisted together. Lay of insulated conductors not specified. |
|
Inner Jacket | Extruded PVC, 94 mils minimum average thickness, 75 mils minimum thickness at any point. |
|
Shield | Optional. A 1-mil Polyester tape and/or a 36 AWG - 30 AWG tinned or untinned copper applied as a wrap or braid. |
|
Outer Jacket | Extruded PVC, 50 mils minimum average thickness, 40 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring and external interconnection of electronic equipment. |
|